Home > Hot Tub > How To Fix Flo Error On Hot Tub

How To Fix Flo Error On Hot Tub

Contents

Hot tub low flow error causes and solutions……. Any questions or comments?  Just ask! -Jen Allen [email protected] Tweet Comments are closed. Spa Guy 1,259 views 2:54 How to Fix an Air Lock in Your Spa : Pools & Spas - Duration: 3:08. FINAL NOTE: Balboa M7 systems have the Temperature Sensor as well as the Hi Limit sensor installed in the heater assembly, one at each end. http://igroupadvisors.com/hot-tub/hl-error-on-hot-tub.php

It's very important to remember that if you just finished fresh filling your spa then you could also have had an air lock that caused a Flashing FLO message. Pressure switch and heating element is fine. I have also tried shutting the hottub off and turning back on with out the filters installed. Turns out the transformer blew out two legs. This Site

Where Is The Flow Switch On A Hot Tub

I ran it without filter and it ran for hours no problem. Sometimes motors with bad bearings can last for months; however the loud noise will only get louder. The steps laid out below is what I have all my customers do when they call me for a low flow error.

Flow switches are plumbed in line with the plumbing. Matt Giovanisci Sounds like you have an issue with your pump. showmehowtofixit 121,666 views 3:41 How to deal with a flow reading on your hot tub - Duration: 4:24. Hydropool Hot Tub Flow Error Lot of learning on this project.

The error codes above are related to a temperature sensor failure, overheat problems or a flow problem. Hydropool Hot Tub Error Codes Nigel August 21, 2016 Reply Damon check your temperature with a couple of external thermometers. Up next Pressure Switch Flow Code No Heat Spa Hot Tub How To The Spa Guy - Duration: 8:14. A bit of a diagnostics that go into looking over the pressure switches themselves.

December 27, 2011 What is this FLO error on my Sundance Spa? Hot Tub Flow Switch Troubleshooting Giving me a headache lol! I replaced the temp sensors but still get the error. Now I've pulled the board and have to get a new relay and solder it on.

Hydropool Hot Tub Error Codes

These pressure switches are non-adjustable. https://aqua-tech.ca/support-posts/my-hot-tub-spas-topside-control-panel-displays-a-flo-message/ About Press Copyright Creators Advertise Developers +YouTube Terms Privacy Policy & Safety Send feedback Try something new! Where Is The Flow Switch On A Hot Tub Matt Giovanisci Have you checked to see if it's a bad control panel? Sundance Hot Tub Flo Error If the breaker does not trip after unplugging the pump, ozonator or blow, you’ve found the problem and you can now replace that component.

But have a tech come our first to verify as that is expensive and you want to be sure. check my blog Frozen water in the Pumps? Request Hot Tub Service & Repair today! Remove solids, break down alkalis, and of course oils. Flc Error Code On Hot Tub

  1. Unfortunately it is a process of elimination. -Jay Tim October 5, 2015 at 3:31 pm So I have a 2006 artesian dove canyon spa.
  2. Matt Giovanisci Hmm..
  3. Better to call someone on this one.

Anne-Marie Bolduc July 22, 2016 Reply Hi, each number (one by one) is flashing on topside controle panel. This sometimes refreshes the pc board software if there is anything funky going on. The heater now tries to kick on every so often for 4 seconds or so but then kicks off. this content It wants to - I keep hearing ‘clicking' as if something's trying to engage - but all that happens is that the temp indicator keeps rising to the point that the

The spa is at a temperature above 108° F. Vita Spa Error Codes It started with the heat element then I replaced it but the circuit board brunt up because I left it running in the rain. Pump 1 is running with the heater like it should.

We have circulation and water falls work.

When you look at the spa, you want to make sure that water is flowing in through the skimmer and that there's no obstructions there. Turned it on later and Pump 1 wouldn't work. admin November 2, 2015 at 9:38 am Hi Jennie, I am not rally familiar with the Spa in the Box style tubs, however if you are not getting the right amount Marquis Spa Error Codes Shut the spa down, remove the filter and make sure all the jets are open.

Any ideas on what to do? To me, it seems that pump is able to move enough water to activate the switch (and a good connection to it). If the pump is not running but the diaphragm is closing the contact you're going to get FLC because it's closed when it's not supposed to be. http://igroupadvisors.com/hot-tub/hot-tub-error-code-flo.php Anyway not positive but possible number 2 pump never worked this year, but I think LF and dry started after leaves were in tub.

But in the last 3 days everytime you turn the Jets on and it runs for 10 minutes it pops the main breaker in the house. You could also have something plugging the circ line and or circ pump. Then turn off, no pressure. Still have the FLO error?  If it's still there, it's time to call a technician.  This could indicate that there is something more extensive wrong, though it could still be a

You're good to go. Most often this will be caused by a leaking shaft seal, or it could happen from old age. Last time I replaced the Flow Switch a couple years ago though was when the FLO error was solid and there was no water circulation and that fixed everything. As far as the pressure switch goes you may be at the point where you would want to jump out the pressure switch and see if the flo error goes away.

After many uses, the temperature seems to go down one day, then went back into normal, 105°. Anything you recommend? So, you pull one of the leads off. It's the correct board.

Your heater burned up from being exhausted from running with the top off. Another thing that you want to check is your skimmer and the filter area. I be the PC board needs to be replaced. -Jay admin October 10, 2015 at 7:34 pm Hi Pete, Sounds like either bad sensors or a bad PC board. -Jay admin Fuse?

But with my experience in such matters I suspect I will again see these warnings. This here is a pressure switch. Came home turned breaker on and now panel shows nothing. HELP!!!!

Once I powered it up, it ran and heated the water. Inspect your Flow Switch for hair or debris wrapped around the paddle. Is anyone familiar with this make of hottub and would you be willing to provide me some feedback on next steps. softcellelectrical 117,217 views 9:12 How To Make a FLOATING HOT TUB - Duration: 4:33.